97视频在线观看免费-97视频在线观看免费播放-97视频在线观看免费视频-97视频在线观看视频最新-97视频在线免费

技術文章您現在的位置:首頁 > 技術文章 > ABB 氧化鋯分析儀 AZ25 AZ20 產品簡介
ABB 氧化鋯分析儀 AZ25 AZ20 產品簡介
更新時間:2017-10-20   點擊次數:3048次

Endura AZ20/AZ25 Oxygen Monitor Combustion gas analysis

ABB 氧化鋯分析儀 AZ25 AZ20 產品簡介

 

Introduction

The Endura AZ20 is the latest in a long line of high-quality, combustion gas analyzers from ABB.

The sensor, based on a zirconium oxide cell, is mounted at the tip of the probe that is inserted in the flue duct. The resulting direct, in situ measurement provides accurate and rapid oxygen reading for combustion control / optimization and emissions monitoring purposes.

Endura AZ20 has been designed for extended periods of maintenance-free operation. The modular design with reduced component count improves the reliability and robustness of the system and simplifies breakdown repair if it occurs.

Kits containing all the parts needed to complete on-site repairs are available from ABB, ensuring that service personnel can effect repairs quickly and efficiently at minimum cost. The Endura AZ20probe has retained an easy-access cell arrangement, similar to the proven ZFG2 probe. This ensures cell replacement can be carried

out on-site using readily available, basic hand tools, even after long periods of high temperature operation.

The Endura AZ20 oxygen probe measures oxygen concentration in flue gas using an in situ 'wet analysis' method. The 'wet analysis' method avoids measurement error (typically20% of reading higher than the actual value) that is introduced by a sampling system using the 'dry analysis' method.

For customers with an existing installed ZFG2 probe with a ZMT or ZDT transmitter, a 55 V heater version of the Endura AZ20probe (the Endura AZ20 / ZFG2 replacement probe) is available.

System equipment comprises a (flue-mounted) Endura AZ20probe controlled by an integral or remote transmitter. During operation, a zirconia cell within the probe is held at a constant temperature of 700°C (1292 °F) by a probe heater and control

thermocouple assembly. If the heater control circuitry or software fails (unsafe), the probe heater power supply is switched off, ensuring the system fails 'safe' and protects the heater from an over-temp failure.

An output generated at the zirconia cell is processed in the transmitter giving a locally displayed O2 reading and a 4 to 20mA retransmission signal over any range between 0 % and 100% O2.

Optional automatic calibration (AutoCal*) enables automatic,semi-automatic or manual calibration to be performed using a probe-mounted gas control manifold mounted within the probehead. Calibration sequencing is software-controlled from thetransmitter.

Optional restrictors (where fitted*) in the probe head control thetest gas and reference air flow without the need for flowmeters.The probe requires only preset test gas and reference airpressures of 1 bar (15 psi) to maintain a constant flow of 2.2 l /min (4.662 scfh). This flow is not affected by changes in themeasured gas pressure of ± 0.35 bar (5 psi). 

Introduction

The Endura AZ25 combustion oxygen analyzer is the latest ina long line of high-quality, combustion gas analyzers fromABB. The AZ25 is designed to measure oxygen concentrationin high temperature furnace atmospheres.

The sensor, based on a zirconium oxide cell, is mounted at thetip of the probe that is inserted directly into the furnace. Theresulting direct, in-situ measurement provides an accurate andrapid oxygen reading, for combustion control / optimizationand process quality control purposes.

The in-situ technique provides a true oxygen measurementinside the process. It eliminates 'equilibrium shift' that iscommon to systems in which gas samples are extracted andcooled before measurement.

Reference air (500 to 1000 ml/min [1 to 2 ft3/hr]) is required foraccurate operation and can be supplied from an ABBmains-powered pump unit or a flow regulator unit.

 

Unique integrated automatic calibration

The Endura AZ25 automatic calibration system eliminates theneed for the expensive ancillary equipment required forautomatic calibration on traditional flue gas oxygen analyzersystems. ABB’s fully integrated, automatic calibration feature

controls the test gas sequence and detects test gasavailability, eliminating incorrect calibrations due to loss of testgas. Integrated automatic calibration secures the oxygenmeasurement, providing complete confidence in the analyzer's

 

performance.

Long-term operation without technician intervention minimizesoperating costs, total cost-of-ownership and optimizes systemaccuracy. A significant proportion of service visits to ananalyzer result in 'no fault found'. Endura AZ25's high-quality

manufacture, advanced diagnostics and automatic calibrationis targeted at reducing this wasted effort and cost.

 

Dependable

— measurement of O2 in a wide variety of processes

— virtually instantaneous response

— resistance to sulphurous reducing atmospheres

 

Versatile

— 600 to 1250 mm (2 to 4 ft) lengths

— choice of protective sheath materials

— integral thermocouple for automatic temperature

compensation

— high temperature operation up to 1400 °C (2552 °F)

 

Low cost-of-ownership

— in situ measurement

— no sampling system required

— automatic calibration functionality as standard

— optional automatic calibration hardware

Applications

— Furnace atmosphere monitoring:

— Annealing furnace

— Sintering of metals

— Ferrite sintering

— Whiteheart malleablizing

— Combustion measurement and control in:

—Soaking pits

—Process heaters

—Fluidized bed boilers

—High temperature incinerators

— All other combustion processes where the flue gastemperature is in excess of 600 °C (1112 °F)

 

Aluminous porcelain

Entry level sheath material suitable for applications withtemperatures up to 1250 °C (2282 °F) – limited resistant tocorrosive chemicals and mechanical and thermal stress.

Recrystallized alumina

Suitable for applications with temperatures up to 1400 °C(2552 °F) resistant to corrosive chemicals and more severemechanical and thermal stress are present.

Incoloy 800

Suitable for applications with temperatures up to 850 °C

(1562 °F) when mounted horizontally and up to 1000 °C

(1832 °F) when mounted vertically.

Offering limited resistance to corrosive chemicals and resistantmechanical and thermal stress.

愛澤工業(IZE_INDUSTRIES)銷售型號示例:

ABB 氧化鋯分析儀AZ25/.1.1.2.1.1.5.3.1.2.0.0.0.0 /STD

ABB 氧化鋯分析儀AZ25/.1.1.2.1.1.5.1.1.1.1.0.0.0.0

ABB 氧化鋯分析儀AZ25/.1.1.2.1.1.5.1.1.1.1.0.0.0.0.E./STD

ABB 氧化鋯分析儀AZ25/.1.1.2.1.1.5.3.1.2.0.0.0.0.E.Z.J/STD

ABB 氧化鋯分析儀AZ20/112112225111100C/STD

ABB 氧化鋯分析儀AZ20/1.2.2.2.1.2.2.3.3.7.1.1.2.E

ABB 氧化鋯分析儀AZ20/222122337112E

ABB 氧化鋯分析儀AZ20/2.2.2.1.2.2.3.3.7.1.1.21.0.0.E/STD

ABB 氧化鋯分析儀AZ20/222122337112E/STD

 

如果您有任何關于產品的相關技術咨詢或者需要產品的相關技術資料與文檔,請隨時愛澤工業,或者訪問我們將盡全力解決您的問題。

If you have any question, please feel free to dial or browse our website. Thank you.

主站蜘蛛池模板: 在线中文字幕日韩 | 午夜hhh视频在线观看hhhh | 黄色毛片电影 | 亚洲精品久久久久久久福利 | 国产目拍亚洲精品区一区 | 色婷婷亚洲五月色综合色 | 久久久精 | 欧美人在线视频 | 色综合天天色综合 | 久久国产亚洲精品麻豆 | 国产香蕉98碰碰久久人人 | 日本一级毛片大片免费 | 国产精品毛片在线大全 | 国产区精品视频 | 国产精品喷水在线观看 | 制服丝袜 自拍偷拍 | 欧洲美女大片免费播放器视频 | 亚洲国产精品一区二区久久 | 色爱区综合激月婷婷激情五月 | 精品欧美一区二区三区免费观看 | 免费黄色福利视频 | 国产精品欧美韩国日本久久 | 宅男午夜剧场 | 国产成人久久蜜一区二区 | 国产一级一级 | 国产丝袜脚 | 91视频精选 | 亚洲精品久久一区影院 | 久久久夜色精品国产噜噜 | 欧美啪视频 | 看免费的毛片 | 国产一 | 成人区视频 | 影院色 | 国产免费变态视频网址网站 | 国产一区二区三区四区在线 | 骚黄视频| 日本黄色一级网站 | 广东东莞一级毛片免费 | 国产精品欧美韩国日本久久 | 欧美日一区 |